UV-4100PC and UV-3100PC Double Beam Ultraviolet Visible Spectrophotometer
Unicom-Optics UV-4100PC and UV-3100PC Double Beam UV/VIS Spectrophotometers can meet the broad requirements of pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analyses, kinetics, spectrum scanning, multiple components and DNA/Protein.
UV-4100PC and UV-3100PC Double Beam UV/VIS Spectrophotometers must link with PC. (PC not included).
The two detectors are measuring sample and reference respectively and simultaneously for optimizing measurement accuracy. It provides excellent performance for measurements in the range of 190nm to 1100nm. It is suitable for pharmaceutical, biochemical and clinical lab applications as well as routine applications such as quantitative analyses, kinetics, spectrum scanning, multiple components and DNA/Protein. PC Windows® application software makes this instrument versatile.
Features for UV-4100PC and UV-3100PC
|
● |
Non-volatile memory storage and one-button easy recall |
|
● |
Pre-aligned deuterium lamp for easy lamp replacement. Lamp usage and the status of the lamps may be monitored |
|
● |
Real-time clock for date and time stamping of results |
|
● |
Full CE compliance |
|
● |
PC Windows® software including sophisticated utility programs |
|
● |
Full A4 print-outs of graphs and tables of results with popular inexpensive printers such as HP or Epson Deskjet |
|
● |
Performance validation and report (GLP compliance) |
|
|
|
Specifications for UV-4100PC and UV-3100PC
|
Model |
UV-4100PC |
UV-3100PC |
|
|
|
|
Optical Specifications |
|
|
Wavelength Range |
190 - 1100 nm |
|
Spectral Bandwidth |
1 nm |
2nm |
|
Monochromator |
Double beam C-T type, grating 1200 lines/mm |
|
Wavelength Accuracy |
± 0.3 nm |
|
Wavelength Repeatability |
± 0.2 nm |
|
Wavelength Calibration |
Automatic at start |
|
Light Source |
Tungsten Halogen Lamp
Deuterium Lamp |
|
Detector |
Solid Silicon Photodiode |
|
Photometric Readout |
UVCON Software |
|
Photometric Range |
0 - 200%T -0.3 - 3.0A 0 - 9999C |
|
Photometric Accuracy |
Better than 0.3% at 0.5A, 1A, 2A |
|
Zero Drift |
< 0.0003A per hour after warm-up |
|
Baseline Flatness |
± 0.001A |
|
Stability |
± 0.0004A/h at 500 nm |
|
Stray Light |
< 0.05% at 200 nm and 340 nm |
|
Scanning Capability |
Yes |
|
|
|
|
Physical Characteristics |
|
|
Standard Sample Holder |
4-position Cell Holder |
|
Analogue/Digital Output |
Digital, RS232 Serial, Centronics Parallel |
|
Dimensions |
550(L) x 400(W) x 260(H) |
|
Weight |
25 kg |
|
Shipping Dimensions |
to be updated |
|
Shipping Weight |
to be updated |
|
Power Requirements |
115V/60Hz or 230V/50Hz, switchable |
|
Operating Temperature |
Room temperature: 22 ± 2°C |
|
Humidity Range |
≤ 85% relative |
|
Safety Certificate |
CE |
Features for Windows®-Based Application Software
|
● |
Basic Mode |
|
|
Abs/%T/Con Test. |
|
● |
Quantitative (Standard Curve) |
|
|
Use up to 32 standards to establish standard curve.
Four methods for fitting a curve:
1. Linear fit
2. Linear through zero
3. Square fit
4. Segmented

|
|
|
|
|
● |
Wavelength Scanning |
|
|
Automatically record peaks and valleys.
Post-run manipulation and processing includes:
1. Re-scaling axes, curve
2. Smoothing, combination, zooming, overlap…
3. 1st to 4th derivative

|
|
|
|
|
● |
Time scanning |
|
|
Abs. vs. time graphs is displayed on the screen in real time. Wait time, measurement time and time intervals may be entered. Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.

|